Heat Exchanger Unit for Hotel Heating

Product Details
Customization: Available
Warranty: 1 Year
Certification: CE, ISO, SGS, TUV
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
122
Year of Establishment
2005-09-06
  • Heat Exchanger Unit for Hotel Heating
  • Heat Exchanger Unit for Hotel Heating
  • Heat Exchanger Unit for Hotel Heating
  • Heat Exchanger Unit for Hotel Heating
  • Heat Exchanger Unit for Hotel Heating
  • Heat Exchanger Unit for Hotel Heating
Find Similar Products
  • Overview
  • Product Description
  • Structure
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Application
Heater, Cooler, Condenser
Principle
Mixing Heat Exchanger
Style
Plate Type
Material
Stainless Steel
Performance
Pressure Resistant, Temperature Resistant, Corrosi
Customized
Customized
Application Scope
Food, Beverage, Pharmacy, Cosmetic
Frame Material
Carbon Steel
Plates Material
AISI 304/316L, Hastelloy, Smo 254, Ni, Ti
Gasket
NBR, EPDM
Transport Package
Polywood Box
Specification
ISO9001: 2008, SGS
Trademark
JIEMA
Origin
Guangzhou, China
HS Code
8419909000
Production Capacity
100 Million USD Per Year

Product Description

Heat Exchanger Unit for Hotel Heating   
 
 
Product Description

The plate heat exchanger is a new efficient and compact heat exchanger that has developed and extensively used in recent decades. It consists of multiple parallel corrugated-surface thin metal sheets that overlap and are then fixed by lamp plates and bolts. The cold working fluid and the hot working fluid flow through the narrow and winding passage made of two neighboring plates alternately and realize cold and heat exchange through the plates separating the two working fluids.

Heat Exchanger Unit for Hotel Heating
Heat Exchanger Unit for Hotel Heating


 
Structure

The plate heat exchanger consists essentially of heat transfer plates, gaskets and a clamping device. Thanks to its structure and heat exchange principle, it is characterized by compact structure, small floor area, high heat transfer coefficient and operation flexibility, wide application range, small heat loss, easy installation and cleaning, etc. The two mediums have a mean temperature difference as small as 1ºC and heat recovery efficiency higher than 99 percent. Based on the same pressure loss, the plate heat exchanger has, compared with a tubular heat exchanger, a heat transfer coefficient two to four times higher, a one-third floor area and two-thirds metal consumption. It is therefore an efficient and energy, material and investment saving advanced heat exchanger. It is now widely used in industrial fields such as chemical industry, petrochemical, food, machinery, central heating, metallurgy, power, ships, paper-making, textile, pharmaceutical industry, nuclear industry, seawater desalination and combined heat and power generation to meet the requirements of processes such as cooling, heating, condensation, concentration, sterilization and residual heat recovery. It has become a highly competitive product in the heat exchanger field or evenly has replaced conventional tubular heat exchangers. With its development, it will be used in more and more fields.

Heat Exchanger Unit for Hotel Heating


 
Product Parameters

Plate and gasket

The plate materials and the gasket materials mainly depend on the corrosive properties and temperatures of the cold exchange medium and the heat exchange medium. The plate heat exchanger's plate materials and corresponding applicable places are given in Table 1 and its gasket materials and corresponding applicable places in Table 2 for your reference.

Table 1 Plate Materials

 
Material name Thickness (mm) Material grade Applicable place
Stainless steel 0.5-0.8 304,321,316,316L
Places with serious corrosion caused by acid or base mediums and places not suitable for chloride ions
Commercial pure titanium 0.5-0.8 Ti Alkali or salt making places, sea water desalination places, low-temperature places, freezing places or places with chloride-ion corrosion
Nickel 0.5-0.8 Ni Places resistant to corrosion, hot alkali liquor corrosion, neutral solutions or subacid solutions
Acid-resistant steel 0.5-0.8 RS-2, SM0254, HC-276 Sulfuric acid field and the fields with acid corrosion

Table 2 Gasket Materials
 
Material name Code Applicable temperature Applicable place
NBR N -20~110ºC Water, non-polar oil, mineral oil, lubricating oil, silicon oil, etc.
EPDM E -20~150ºC Steam, water, ozone, polar chemical mediums, alcohol, weak acids, weak bases, salt solutions, etc.
Chloroprene rubber C -40~100ºC Ammonia, mineral roil, lubricant, freon, etc.
Fluororubber F 0~180ºC Inorganic acids, bases, mineral oil, halohydrocarbon and oxidant
Silicon rubber Q -40~200ºC Food field, etc.


Our factory:

Heat Exchanger Unit for Hotel Heating

Company Profile

 

Heat Exchanger Unit for Hotel HeatingHeat Exchanger Unit for Hotel HeatingHeat Exchanger Unit for Hotel HeatingHeat Exchanger Unit for Hotel HeatingHeat Exchanger Unit for Hotel HeatingHeat Exchanger Unit for Hotel Heating


 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier