• High Efficiency Screw Water Chiller Unit with Air Cooled Condenser
  • High Efficiency Screw Water Chiller Unit with Air Cooled Condenser
  • High Efficiency Screw Water Chiller Unit with Air Cooled Condenser
  • High Efficiency Screw Water Chiller Unit with Air Cooled Condenser
  • High Efficiency Screw Water Chiller Unit with Air Cooled Condenser
  • High Efficiency Screw Water Chiller Unit with Air Cooled Condenser

High Efficiency Screw Water Chiller Unit with Air Cooled Condenser

After-sales Service: 24 Hours After-Service
Warranty: 1 Year
Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 220V/50HZ
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Customized
Compressor Number
1
Noise Level
Low
Application Fields
Food Processing
Application Machine
Machining Center
Certification
ISO, CE
Condition
New
Component
Compressor, Evaporator, Condenser, Expension Valve
Transport Package
Plywood Box
Specification
Customized
Trademark
JIEMA
Origin
Guangzhou
HS Code
8418692090
Production Capacity
1500 Sets/Year

Product Description

Brief Introduction

The air-cooled screw flooded unit uses an advanced 5:6 high-performance screw compressor as the refrigeration "heart" to match high-quality condensers and evaporators, and is equipped with brand-name electrical control components. Suitable for all kinds of cooling and heating places.

Design Parameters
Refrigeration range: 25kw~118.7kw        
Chilled water temperature adjustment: 5~20ºC
Application areas: industrial and commercial premises with cooling and heating requirements.


Product Characters
High Efficiency Screw Water Chiller Unit with Air Cooled Condenser  EFFICIENT
       The unit adopts a full-liquid evaporator, which reduces energy consumption by 15%-25% compared with similar dry-type products, and the energy efficiency of the whole machine reaches level 2 to level 1.
 
 
   Energy-Saving
      The unit is equipped with our patented heat recovery device, which can recover 30% of the cooling capacity;
          High Efficiency Screw Water Chiller Unit with Air Cooled Condenser 
 
High Efficiency Screw Water Chiller Unit with Air Cooled Condenser   Stable
      The unit is equipped 8 protection devices, including reverse phase protection, phase protection, overcurrent protection, hight and low voltage protection, low temperature portection, water flow protection and so on, which can ensure the normal operation of the unit.

    
High Efficiency Screw Water Chiller Unit with Air Cooled Condenser  Customized
       The unit can be designed and manufactured with different size ans structure to meet the different needs of customers;
        The unit can provide refrigerants such as R134a and R22 according to customer needs.
 
High Efficiency Screw Water Chiller Unit with Air Cooled Condenser  RELIABLE                                
        16-year experience in heating and cooling field
       2 production bases--Guangzhou, Hubei


       Strong technical team--5 senior engineers (over 15 years experience)
       Quality guaranteed --  CE,SGS,ISO9001 certified, 18 patents
       Warranty--
1 year guarantee and 10 years service

                                            

Installation and Maintanance
1. It can be installed on the roof platform of a building or in other well-ventilated environments without additional cooling water system;

2. It is recommended to install multiple units in parallel during transportation, lifting and installation;

3. The installation environment of the unit should be kept dry and ventilated. The ambient air should not contain corrosive substances, and avoid close to chimneys, generators, boilers and other places that are prone to generate acid gas or emit large amounts of heat;

4. In order to prevent the bottom of the unit from rusting, it is easy to use a cross steel frame to support the bottom of the unit during installation, so that the unit is not less than 20cm from the ground;

5. Anti-vibration soft joints should be installed at the inlet and outlet of cold (hot) water pipes, and at the front and rear of the cold (hot) water pump. Gate valve thermometer, water pressure gauge, water flow switch on the outlet side of the heat exchanger, filter and other auxiliary devices on the inlet side of the water pump;

6. When configuring the power cord, please choose a wire with a larger cross-sectional area, so that the flow rate of the power cord is not less than 20%.
 
 
For more information, feel free to contact us !

Contact Person:
Ms. Rebecca
High Efficiency Screw Water Chiller Unit with Air Cooled CondenserHigh Efficiency Screw Water Chiller Unit with Air Cooled CondenserHigh Efficiency Screw Water Chiller Unit with Air Cooled CondenserHigh Efficiency Screw Water Chiller Unit with Air Cooled CondenserHigh Efficiency Screw Water Chiller Unit with Air Cooled Condenser

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
122
Year of Establishment
2005-09-06